title: "Appliance hook-ups: what each new unit needs from the house"
description: "A one-page map of connections by appliance group, covering gas, water, drain, exhaust and power, with what is usually there already and what an installer has to…"
url: "https://applianceinstallation.center/guides/appliance-hook-ups-what-each-unit-needs/"
date_modified: "2026-11-28"
---

Get the space ready

# Appliance hook-ups: what each new unit needs from the house

Appliance hook-ups fall into five kinds: gas, water supply, drain, exhaust and power. Each appliance group needs a different mix; laundry and dish units need water, drain and power, cooking units need power or gas plus exhaust, and cold storage needs power and sometimes water. Gas goes to a qualified installer or the gas utility, wiring to an electrician, water and drain work to a plumber.

By [ApplianceInstallation.center technical team](https://applianceinstallation.center/authors/technical-team/) Published November 28, 2026

## At a glance.

Before a new appliance arrives, the house has to be ready to feed it: a supply, a way out for water or air, and power. Knowing which of those each group needs tells you what to check, what to buy and who to book.

Read the whole guide

### Five kinds Gas, water supply, drain, exhaust, power

### Gas A qualified installer or the gas utility only

### Power An electrician for new outlets, circuits and wiring

### Check first The installation sheet for your exact model

In this guide

1. What kinds of hook-up does a new appliance need?
2. Which connections does each appliance group need?
3. How do gas and power differ from water and drain?
4. What about water, drain and exhaust?
5. How do you check the house before ordering?
6. Questions

## What kinds of hook-up does a new appliance need?

Every household appliance draws on some mix of five connections: gas, water supply, drain, exhaust and power. Each group needs its own mix, and a missing one is a common reason a delivery sits in the hallway.

### Reading the list

Gas feeds a flame; water supply feeds a fill valve; a drain carries used water out; exhaust carries heat, moisture or smoke outdoors; power runs controls, motors and elements. Your new unit's installation guide lists which of these it needs, and the spec sheet gives the sizes.

## Which connections does each appliance group need?

The table is a starting map; the installation sheet for your model is the authority. "Maybe" means it depends on fuel or on a feature such as a water dispenser or a steam cycle.

*Connections by appliance group, with maybe where fuel or features decide.*

| Group | Gas | Water | Drain | Exhaust | Power |
| --- | --- | --- | --- | --- | --- |
| Laundry (washing) | No | Yes, usually hot and cold | Yes | No | Yes |
| Laundry (drying) | Maybe | Maybe | No | Yes | Yes |
| Dish care | No | Yes | Yes | No | Yes |
| Cooking | Maybe | No | No | Maybe | Yes |
| Cold storage | No | Maybe | No | No | Yes |

### What is usually there already

In a home that has had such an appliance before, the old connections are often in place: the shutoff valves, the standpipe, the vent, the outlet or the gas stub. They are not always the right size, in good condition, or the right type for the new model, so test and compare them rather than assuming.

### Where the connections sit

Connections cluster behind or beside the opening. Water boxes and shutoffs sit in the wall or under the nearest sink, a gas stub rises from the floor or wall at a cooking or drying position, a vent passes through the wall or floor, and outlets sit low on a side wall or inside an adjacent cabinet. Mark each one with painter's tape on the day you measure, so that the crew sees what you intend to use.

### What often has to be added

Typical additions are a new supply line or a connector, a drain fitting or air gap, a longer vent, a different outlet or cord, and an anti-tip bracket. Freestanding and slide-in ranges ship with an anti-tip device, and the installation instructions say to fit it before the range is used. [The rough-ins guide](https://applianceinstallation.center/guides/water-drain-and-exhaust-rough-ins/) explains what must be in the wall before the unit arrives.

A close view of a braided water supply line attached to a wall shutoff valve with a small drip towel under the fitting.

## How do gas and power differ from water and drain?

Gas and power carry safety risks that water does not: fire, explosion, shock and carbon monoxide. That is why the work is split by trade and not left to the owner.

- Gas: a qualified installer connects the appliance, sets up the connector and shutoff, converts the unit if needed, and leak-tests. [Gas connectors, conversion kits and the leak test](https://applianceinstallation.center/guides/gas-connectors-conversion-kits-and-the-leak-test/) explains what happens, and [the gas hookup and leak check service](https://applianceinstallation.center/services/gas-hookup-and-leak-check/) is where to book it.
- Power: check the outlet type and the circuit against the nameplate, and let an electrician add or change anything. [The circuit and outlet a new appliance needs](https://applianceinstallation.center/guides/the-circuit-and-outlet-a-new-appliance-needs/) covers the groups one by one.

### The smell of gas

If you smell gas at any point, do not operate switches, lighters or phones inside. Leave, and call the gas utility from outside. [A gas smell after hookup](https://applianceinstallation.center/problems/gas-smell-after-hookup/) describes what to expect afterward.

## What about water, drain and exhaust?

These connections are simpler but leak or clog in ways that do slow damage, so they deserve a careful look. A weeping fitting under a unit can rot a subfloor before anyone notices.

### Water supply

A supply line runs from a shutoff valve to the unit's inlet. The installer fits a new line of the type the instructions call for, and a plumber replaces a corroded valve or adds a missing one. Your part is to watch while the valve is opened slowly and look for drips. [A water supply and shutoff connection](https://applianceinstallation.center/services/water-supply-and-shutoff-connection/) covers this when the valve or line needs replacing, and [a leak after install](https://applianceinstallation.center/problems/water-leak-after-install/) lists what to check if one appears.

### Drain

A dish-care drain hose needs a high loop or an air gap, as the instructions and local code require, so that used water cannot siphon back. A laundry hose goes into a standpipe or laundry sink at the height the manual gives. [A drain and air gap connection](https://applianceinstallation.center/services/drain-and-air-gap-connection/) sets that up where the house has none.

### Check the reach

Leave slack. A cord, hose or connector pulled tight behind a unit is a leak or a shock risk once the unit is pushed into place, and it prevents the unit from sliding out for later service. Measure from the connection to the unit's inlet with the unit in its final position, not from where it stands on delivery day.

### Exhaust

Drying and cooking units push moist or hot air out, and the duct must be short, smooth, and open to the outside. A crushed or disconnected run is a fire and mold risk, and [laundry exhaust run installation](https://applianceinstallation.center/services/laundry-exhaust-run-installation/) covers a new run.

## How do you check the house before ordering?

Go through the map for your unit, group by group, and tick every connection against what the wall actually shows. Doing this before you order is cheaper than finding a gap on delivery day.

1. List the connections the spec sheet requires.
2. Find each one at the opening and note its type, size and condition.
3. Compare plug shape, valve type and vent size with the sheet.
4. Write down what is missing, and who you will book for it.
5. Book the trades before the delivery date, not after.

A [pre-installation site check](https://applianceinstallation.center/services/diagnostic-visit/) does the same walk-through and leaves you a written list, if you would rather have someone confirm it.

## Where to stop

Gas connections belong to a qualified installer or the gas utility, never to the owner. New outlets, circuits and hardwired connections belong to an electrician. If you smell gas, leave the house and call the gas utility from outside; if a fitting leaks, close the water shutoff and call a plumber.

Written by [ApplianceInstallation.center technical team](https://applianceinstallation.center/authors/technical-team/). Installers who fit new household appliances, writing from real openings and hookups and each maker's installation instructions.

For the heart of your home.

## Questions owners ask.

### Can I connect a new appliance to the old connections?

Often yes, but check them first. Old supply hoses, brittle vents and mismatched plugs are common. Have the installer fit new lines and a new gas connector, confirm the outlet matches the plug, and have gas and wiring checked by the right trade.

### Who connects the gas, the water and the power?

A qualified installer or the gas utility handles gas, a plumber handles new or replaced water and drain lines, and an electrician handles new outlets and wiring. Many crews connect only a plug and a water line, so ask what is included.

### What if the plug does not match the outlet?

Do not alter the plug or use an adapter. Ask an electrician to install the correct outlet for the unit, and confirm the circuit rating first; a mismatch is common and fixable before the unit is connected.

### Which connections do I need to check for a cold-storage unit?

Usually just a grounded outlet and, if there is an ice maker or water dispenser, a water line with a shutoff. Check the cord reaches without strain, and that the water line is long enough to let the unit slide out.

## The problems behind it.

Each has a page of its own: what it usually means and the causes in the order worth checking.

[All 17 problems](https://applianceinstallation.center/problems/)

Hazard after a hookup

### Gas Smell After a Hookup: Leave the House, Then Call

6 causes, cheapest first

Hazard after a hookup

### Water Leak After an Install: Close the Supply Valve First

6 causes, cheapest first

Hazard after a hookup

### Breaker Trips on the First Run: Leave It Off and Find Out Why

6 causes, cheapest first

## When it needs a technician.

The installations on the right are where this guide ends when the checks do not settle it.

### Gas hookup and leak check

A new gas appliance joined to your shutoff with a new connector, every joint leak-tested, flames read.

### Water supply and shutoff connection

New supply lines from a working quarter-turn stop to each water appliance, tested under pressure.

### Drain and air gap connection

Drain hoses run through a high loop, air gap or standpipe, clamped and proved on a first drain.

## More in get the space ready.

Everything worth having ready before delivery: an opening that matches the maker's cutout drawing, a clear path through doors, stairs and floors, and the water, drain and exhaust rough-ins the new appliance will need.

[The whole section](https://applianceinstallation.center/guides/installation-and-setup/)

The opening, the path in and the rough-ins

### Gas appliance hookup: what the visit includes and what to prepare

A gas appliance hookup is more than one pipe fitting. See the valve, connector, outlet, vent and stability pieces behind it, and what to have ready before the installer arrives.

The opening, the path in and the rough-ins

### Appliance installation booking: what the installer needs to know

Gather model numbers, photos of the hookups and shutoffs, opening sizes, stairs and what is being removed, so the first visit finishes the job instead of ending in a second trip.

The opening, the path in and the rough-ins

### Cutout dimensions and the spec sheet: reading the numbers before cabinets are built

Product size, opening size and the clearances above and beside the appliance are three different sets of figures. How to read them on a spec sheet before anyone cuts a cabinet.

The opening, the path in and the rough-ins

### The delivery path: doors, stairs and floors between the truck and the opening

Every doorway, turn and stair the appliance must pass, the weight the floor has to carry, what to inspect before the crew leaves, and how the old unit should leave the house.

The opening, the path in and the rough-ins

### Water, drain and exhaust rough-ins: what must be in the wall before the appliance

Supply stubs, drain heights, air gaps, standpipes, laundry exhaust openings and hood ducts: the rough-in figures the installation instructions give, and why they are set before the walls close.

Guides

### All 27 guides

Six sections, by what you are trying to find out.

---

**[Read on the site: Appliance hook-ups: what each new unit needs from the house](https://applianceinstallation.center/guides/appliance-hook-ups-what-each-unit-needs/)**

**[Book a visit with ApplianceInstallation.center](https://applianceinstallation.center/schedule/)**